ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range Resolution Accuracy
600mV
˜
600V 0.1mV
˜
0.1V ± (0.5% + 4 digits)
1000V 1V ± (0.8% + 10 digits)
Overload Protection: 1000V Input Impedance (Nominal): 10MΩ, <100pF
Input Impedance (Low Z): 3kΩ, <200pF, up to 600V RMS
AC Voltage Measurement
Range Resolution
Accuracy
40Hz ~ 400Hz
Accuracy
400Hz ~ 5kHz
600mV 0.1mV
± (0.75% + 5 digits)
± (2.0% +3 digits)
6V ~ 600V 1mV ~ 0.1V ± (2.0% +3 digits)
1000V 1V ± (0.75% + 8 digits) ± (2.0% +3 digits)*
continued on next page.
Overload Protection: 1000V RMS Input Impedance (Nominal): 10MΩ, <100pF
Input Impedance (Low Z): 3kΩ, <200pF, up to 600V RMS
Frequency Response: 40 to 5kHz Response: True RMS
*Accuracy for 400Hz ~ 1kHz range only.
DC Current Measurement
Range Resolution Accuracy
600μA ~ 400mA 0.1μA ~ 0.1mA ± (1.0% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.5% + 5 digits)
Overload Protection: µAmA: F440mA/1000V fuse / A Input: F11A/1000V fuse
AC Current Measurement
Range Resolution
Accuracy
40Hz ~ 2kHz
600μA ~ 400mA 0.1μA ~ 0.1mA ± (1.2% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.8% + 5 digits)
Overload Protection: µAmA: F440mA/1000V fuse / A Input: F11A/1000V fuse
Frequency: 40 to 2kHz Response: True RMS
Resistance Measurement
Range Resolution Accuracy
600Ω
˜
6MΩ 0.1Ω
˜
0.001MΩ ± (1.0% + 5 digits)
60MΩ 0.01MΩ ± (1.5% + 10 digits)
Overload Protection: 600V RMS
Capacitance Measurement
Range Resolution Accuracy
60nF 0.01nF
± (3.5% + 6 digits)
600nF ~ 6000μF 0.1nF ~ 1μF
Overload Protection: 600V RMS
Frequency Measurement
Range Resolution Accuracy
99.99Hz
˜
499.9kHz 0.01Hz
˜
0.1kHz ± (0.1% + 3 digits)
Overload Protection: 600V RMS Sensitivity: > 0.7V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1
˜
99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS Sensitivity: < 50V
Frequency Range: <10kHz
Diode Test
Overload Protection Range Test Current Open Circuit Voltage
600V RMS 6.0V Appx. 0.25mA
<
1.8V DC (typ.)
Continuity Test
Overload Protection Open Circuit Voltage Threshold (Appx.)
600V RMS
<
0.44V <40Ω
Temperature Measurement
Range Resolution Accuracy
-58 ~ 600°F 0.1°F ± (1.0% + 5.4°F)
-50 ~ 600°C 0.1°C ± (1.0% + 3.0°C)
600 ~ 1832°F 1°F ± (1.0% + 5.4°F)
600 ~ 1000°C 1°C ± (1.0% + 3.0°C)
Overload Protection: 600V RMS Thermocouple Accuracy: Not specifi ed
Specifi cations subject to change
Do Not apply voltage to thermocouple.
• -58° to 1832°F (-50° to 1000°C)
8. Temperature:
Features:
Testing Fuse:
• When selecting uA or mA/A functions the meter will indicate
LEAd” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
Rev B 04/14 139716
7. Frequency (Hz) / Duty Cycle: <500kHz
Features:
HOLD
6. Low Impedance (Low Z): < 600V
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages
• See AC/DC Voltage instruction
Capacitance Features:
HOLD
Safely discharge capacitor before
measurement.
• Reading may take up to 60 seconds
for large capacitors.
SYMBOLS USED ON LCD
~
AC Measurement DC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle Mode Frequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in Ohms Diode Test
F
Capacitance in Farads Continuity Test
Relative / Zero Mode
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
°F
Degrees Fahrenheit
°C
Degrees Celsius
A-HOLD
Auto-Hold Active
LOW
Z
Low Impedance
AUTO HOLD
MAX/MIN REL
HOLD
WARRANTY
www.kleintools.com/warranty
CLEANING
Clean the instrument by using a damp cloth. Do not use abrasive cleaners
or solvents.
Take care to keep the sensor lens clean at all times. Clean the lens using a soft
cloth or cotton swab with water or rubbing alcohol only, and allow the lens to
dry before use.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifi cations
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items
must be properly disposed of in accordance with local regulations.
1000V
10A
Dwg Name: MM2300-139716ART Dwg No: 139716
ECO No: 016671 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
MM2300
MM2300-139716ART-Instructions.indd 1-4 5/5/14 11:41 AM
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - Instruction Manual

CUSTOMER SERVICEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 600691-877-775-5346customerservice@kleintools.comwww.kleintools.comENGLISHInstruction

Strona 2

ENGLISHFEATURE DETAILSMM2300Instruction ManualA. Do not attempt to measure more than 1000V.B. Do not attempt to measure more than 600V on (LOW Z) s

Strona 3 - Manual de

SERVICIO AL CLIENTEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 60069, EE. UU.1-877-775-5346customerservice@kleintools.comwww.kleintools.comManual

Strona 4 - Manual de instrucciones

ESPAÑOLDETALLES DE LAS FUNCIONESMM2300Manual de instruccionesA. No intente medir más de 1000 V.B. No intente medir más de 600 V en la configuración

Strona 5

ATENDIMENTO AO CLIENTEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 60069, EUA1-877-775-5346customerservice@kleintools.comwww.kleintools.comManual

Strona 6 - Manual de instruções

PORTUGUÊSDETALHES DE RECURSOSMM2300Manual de instruçõesA. Não tente medir mais do que 1000 V.B. Não tente medir mais do que 600 V na configuração (L

Strona 7 - Manuel d'utilisation

SERVICE À LA CLIENTÈLEKLEIN TOOLS, INC.450 Bond StreetLincolnshire, IL 600691-877-775-5346customerservice@kleintools.comwww.kleintools.comManuel d&apo

Strona 8

FRANÇAISCARACTÉRISTIQUES DÉTAILLÉESMM2300Manuel d'utilisationA. Ne tentez pas de mesurer des valeurs supérieures à 1000 V.B. Ne tentez pas de

Komentarze do niniejszej Instrukcji

Brak uwag

Dacor Epicure OBSB162 manuals

Owner’s manuals and user’s guides for Barbecues & grills Dacor Epicure OBSB162.
We providing 1 pdf manuals Dacor Epicure OBSB162 for download free by document types: User Manual






More products and manuals for Barbecues & grills Dacor

Models Document Type
Epicure 0B52 User Manual   Epicure Range Cooking Guide, 64 pages
Epicure 0B52 User Manual   Epicure Range Cooking Guide, 56 pages
OBS36 Specifications   Dacor OBS36 Specifications, 55 pages
Epicure 0B36 Operations Instructions   Dacor Epicure 0B36 Operating instructions, 12 pages
OBS36 Operations Instructions   Dacor OBS36 Operating instructions, 12 pages
SGMEM Specifications   Dacor SGMEM Product specifications [es] , 8 pages
EOG52 Operations Instructions   Dacor EOG52 Operating instructions, 12 pages
Epicure 0B52 User Manual   Dacor Epicure 0B52 Product data, 28 pages
Epicure 0B52 User Manual   Dacor Epicure 0B52 Product data, 24 pages
EOG36 Specifications   Dacor EOG36 Specifications, 16 pages
HDER30CLP Specifications Sheet   Dacor HDER30CLP Spec Sheet, 2 pages
HDPR30SNG Specifications Sheet   Dacor HDPR30SNG Specification Sheet EN, 2 pages
HDER36SNG Specifications Sheet   Dacor HDER36SNG Spec Sheet [nl] , 2 pages
HDPR36SNG Specifications Sheet   Dacor HDPR36SNG Spec Sheet, 2 pages
HDER48SNG Specifications Sheet   Dacor HDER48SNG Spec Sheet, 2 pages
HDPR48CLP Specifications Sheet   Dacor HDPR48CLP Specifications Sheet, 2 pages